46 MAC 250 Krypton/Entour
T
ROUBLESHOOTING
Problem Probable cause(s) Remedy
One or more of the fixtures
is completely dead.
No power to fixture.
Check that power is switched on and cables
are plugged in.
Primary fuse blown. Replace fuse.
Secondary fuse(s) blown (located on
PCB inside base).
Check fuses on PCB and replace.
Fixtures reset correctly but
all respond erratically or
not at all to the controller.
The controller is not connected. Connect controller.
XLR pin-out of the controller does not
match pin-out of the first fixture on the
link (i.e. signal is reversed).
Install a phase-reversing cable between the
controller and the first fixture on the link.
Fixtures reset correctly but
some respond erratically
or not at all to the
controller.
Poor data quality
Check data quality (page 13). If much under
100 percent, the problem may be a bad data
link connection, poor quality or broken
cabling, missing termination, or a defective
fixture disturbing the link.
Bad data link connection
Inspect connections and cables. Correct
poor connections. Repair or replace dam-
aged cables.
Data link not terminated with 120 Ohm
termination plug.
Insert termination plug in output jack of the
last fixture on the link.
Incorrect addressing of the fixtures. Check address setting.
One of the fixtures is defective and
disturbs data transmission on the link.
Bypass one fixture at a time until normal
operation is regained: unplug both connec-
tors and connect them directly together.
Have the defective fixture serviced by a
qualified technician.
XLR pin-out on fixtures does not
match (pins 2 and 3 reversed).
Install a phase-reversing cable between the
fixtures or swap pins 2 and 3 in the fixture
that behaves erratically.
Shutter closes suddenly.
The color wheel, gobo wheel, or a
gobo has lost its index position and the
fixture is resetting the effect.
Contact Martin technician for service if the
problem persists.
No light and
 error
message displayed.
The power supply settings do not
match local AC voltage and frequency.
Disconnect fixture. Check settings (“AC
power” on page 7) and correct if necessary.
Lamp missing or blown Disconnect fixture and replace lamp.
Lamp cuts out
intermittently.
Fixture is too hot.
Allow fixture to cool.
Clean fan.
Make sure air vents at control panel and
front lens are not blocked.
Turn up the air conditioning.
The power supply settings do not
match local AC voltage and frequency.
Disconnect fixture. Check settings (“AC
power” on page 7) and correct if necessary.
Table 8: Troubleshooting