Martin RoboColor III Guía de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 61
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
APPENDIX A DIP switch settings for Martin intelligent light units
To achieve proper control of the Units connected to the 2308 Controller you will have to
address these so they match with the controller configuration, or vice versa. You can use
any of the addresses from 1 through 8. If you are not sure about this procedure then refer
to the user’s manual for the particular Unit for detailed information.
The following table shows which DIP-switches that you will have to switch on in order to
address any of the eight controller channels.
DIP-Switch settings
Unit/Channel no. DIP-switch ON
1
2
3
4
5
6
7
8
1
2
1,2
3
1,3
2,3
1,2,3
4
Martin 2308 Controller Version 2.1/3.1 Page 25