22 Service Atomic 3000 user manual
S
ERVICE
7
Warning: High voltage! Do not remove the rear panel. There are no user-
serviceable parts inside.
FUSE REPLACEMENT
The Atomic 3000 uses a 20 amp time-delay fuse for protection against current
overload. If the power diode does not light when power is applied, the fuse may
be spent. If the fuse blows repeatedly, there is a fault with the unit that requires
service by a Martin technician.
Never bypass the fuse or replace it with one of another size or rating.
Replacement fuses may be ordered by P/N 05020040.
To replace the fuse
1 Disconnect the fixture from AC power.
2 Unscrew the fuse holder, located on the side plate nearest the power cord.
Remove the spent fuse from the holder and replace it with an identical 20 amp
6.3 x 32 mm time-delay fuse.
3 Replace the fuse holder in the side plate.
FIRMWARE UPDATES
If you suspect that the firmware installed on your Atomic 3000 has become
corrupted, please contact your Martin dealer for assistance.