MAC 250 / MAC 250+
MAC 250+ 18.3° configuration
Luminous intensity (cd)
-12˚ -9˚ -6˚ -3˚ 0 3 6 9 12
Illuminance (lux or fc)
0 5 10 15 20 25 30 35 40
Distance (m or ft)
Field diameter (m or ft)
Distance (m or ft)
0 5 10 15 20 25 30 35 40
Illuminance (lux or fc) . . . . . . . . . . . . . . . . .245,826 cd / distance
2
(m or ft)
Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.30 x distance
Field angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18.3
°
Measurement conditions . . . . . . .230 V, 50 Hz; no color or effects applied
Measurement source . . . . . . . . . . . . . . . . . . . . . . . . . . .Philips MSD 250/2
MAC 250 MAC 250
+
12 dichroic color filters 12 replaceable dichroic color filters
8 replaceable patterns 8 replaceable indexible patterns
17˚ standard beam angle 18.3˚ fixed beam
with 14˚ narrow angle and with achromatic lens
23˚ wide field options
Degrees from center