12 MAC 250 Krypton
where you want some fixtures to mirror the performance of others with the same DMX address, or when
fixtures are not oriented as programmed.
•
PTSP, the pan/tilt speed menu, provides 3 settings: FAST, NORM and SLOW. NORM is best for
most applications.
FAST provides better performance in applications where speed is most important.
•
SCUT, the shortcuts setting which can be found under the PERS (personality) menu, determines whether
the color and gobo wheels scroll past open when changing positions. When set to
ON, the wheels can “take
a shortcut” and scroll through open when this is the shortest path to the next position. The wheels do not
scroll past open when
SCUT is set to OFF.
DISPLAY
The display menu (PERS>dISP) determines whether the display remains lit or not. Select ON to have
the display remain lit, or OFF to extinguish the display two minutes after the last key press.
To flip the display for easier reading, press [up] and [down] simultaneously.
The display intensity setting (
PERS>dINT) controls display brightness. You can select AUTO for
automatic dimming of the display using the built-in light sensor, or manually select an intensity level from 10
to 100.
LAMP POWER
There are two settings that modify lamp control: Automatic Lamp On (PERS>ALON) and DMX Lamp-Off
(
PERS>DLoF).
There are three options for automatic lamp control: ON, OFF, and DMX. When ALON is OFF, the lamp
remains off until a lamp-on command is received from the controller. When
ALON is ON, the lamp strikes
automatically after the fixture is powered on. When
ALON is set to DMX, the lamp strikes automatically
when the fixture receives DMX data, and it extinguishes automatically 15 minutes after DMX data is lost.
When ALON is either ON or DMX, lamp strike timing is determined by the fixture address to prevent all
lamps from striking at once.
The DMX Lamp-Off setting effects how the lamp can be turned off. When
dLOF is ON, lamp power can be
switched off by sending a DMX value from 248 to 255 on channel 1 for five seconds. When
dLOF is OFF,
the lamp-off command will not work unless special conditions are met. Refer to the DMX protocol.
RESET
The fixture can be reset from the controller if DMX reset (PERS>dRES) is set to 5SEC. If DMX reset is
OFF, this command will not work unless special conditions are met. Refer to the DMX protocol.
DEFAULT SETTINGS
The fixture can be reset to its factory default settings by selecting dFSE>FACT>LOAd.
Information readouts
POWER-ON HOURS
Read the total number of hours the fixture has been on since fabrication (INFO>TIME>HRS>TOTL),
and the number of hours on since the counter was last reset (
INFO>TIME>HRS>RSET). This can be
used to track maintenance intervals. Press [up] for 5 seconds while displayed to reset.
LAMP HOURS
Read the total number of lamp hours since fabrication (INFO>TIME>L HR>TOTL), and the number
of lamp hours since the counter was last reset (
INFO>TIME>L HR>RSET). Reset this counter after
installing a new lamp. Press [up] for 5 seconds while displayed to reset.