MAC
250 and
MAC
250
+
If the control panel does not work, boot mode can be engaged by
moving jumper PL121 on the main circuit board to pins 1 and 2 as
follows.
1.
Disconnect the fixture from AC power. Remove the plastic
cover from the arm opposite the side with the visible motor.
2.
Move jumper PL121 to pins 1 and 2 (hard boot setting).
See also the diagram on page 26.
3.
Perform a boot-mode upload as described in the uploader manual.
4.
Disconnect the fixture from AC power. Move the hard boot jumper back to the normal setting and
replace the cover.
Changing voltage and frequency settings
If the factory voltage and frequency setting, shown on the serial number label, does not match local conditions, rewire
the fixture as follows.
1.
Disconnect the fixture from AC power. Remove the top base cover closest to the power inlet.
2.
Find the correct setting for your AC voltage and frequency in Table 7.
3.
Locate the 7-terminal connection block inside the base. Move the blue wire to the 0 or 20 V terminal,
the brown wire to the 120, 230, or 250 V terminal; and the black wire to the 50 or 60 Hz terminal as
shown for each setting in Figure 12.
Local
AC Voltage
50 Hz
Setting
60 Hz
Setting
Maximum power
(watts)
Maximum current
(amps)
95 - 110 V 100 V, 50 Hz 100 V, 60 Hz 350 4.1
110 - 130 V 120 V, 50 Hz 120 V, 60 Hz 350 3.2
200 - 220 V 210 V, 50 Hz 210 V, 60 Hz 370 2.2
220 - 240 V 230 V, 50 Hz 230 V, 60 Hz 360 1.8
240 - 260 V 250 V, 50 Hz 250 V, 60 Hz 370 1.7
Table 7: Power supply settings and consumption
PIN 1
È
PL121 PL121
PIN 1
È
hard boot settingnormal setting
Figure 11: Hard boot jumper
0 V
20 V
120 V
230 V
250 V
60 Hz
50 Hz
100 V / 50 Hz
BLUE
BROWN
BLACK
0 V
20 V
120 V
230 V
250 V
60 Hz
50 Hz
120 V / 50 Hz
BLUE
BROWN
BLACK
0 V
20 V
120 V
230 V
250 V
60 Hz
50 Hz
210 V / 50 Hz
BLUE
BROWN
BLACK
0 V
20 V
120 V
230 V
250 V
60 Hz
50 Hz
230 V / 50 Hz
BLUE
BROWN
BLACK
0 V
20 V
120 V
230 V
250 V
60 Hz
50 Hz
250 V / 50 Hz
BLUE
BROWN
BLACK
0 V
20 V
120 V
230 V
250 V
60 Hz
50 Hz
100 V / 60 Hz
BLUE
BROWN
BLACK
0 V
20 V
120 V
230 V
250 V
60 Hz
50 Hz
120 V / 60 Hz
BLUE
BROWN
BLACK
0 V
20 V
120 V
230 V
250 V
60 Hz
50 Hz
230 V / 60 Hz
BLUE
BROWN
BLACK
0 V
20 V
120 V
230 V
250 V
60 Hz
50 Hz
250 V / 60 Hz
BLUE
BROWN
BLACK
0 V
20 V
120 V
230 V
250 V
60 Hz
50 Hz
210 V / 60 Hz
BLUE
BROWN
BLACK
Figure 12: Voltage and frequency settings