16 Service and Maintenance RoboColor III
2 On the ballast, move the BLACK wire to the correct voltage terminal. Use the
following table to select the correct voltage setting.
3 Re-assemble the unit.
FUSES
Should the RoboColor III system cease to work it may be due to a blown fuse.
This section describes how to replace the fuses.
To replace the primary fuse
• The primary fuse is located inside the IEC mains input socket at the rear of
the controller. Use a small screwdriver to pry open the fuse holder and
replace the fuse with one of the same size and rating. The fuse rating is also
printed on the serial number label.
50 Hz Model 60 Hz Model
Mains supply Ballast tapping Mains supply Ballast tapping
210V - 235V 230V 200V - 215V 210V
235V - 245V 240V 215V - 225V 220V
245V - 255V 250V 225V - 235V 230V
Ballast
210V/60Hz
230V/60Hz
220V/60Hz
Ballast
230V/50Hz
250V/50Hz
240V/50Hz
50 Hz Version
60 Hz Version
IEC mains input
socket.
Mains fuse
6.3AT/250V (slow
Comentarios a estos manuales