Error messages 43
E
RROR
MESSAGES
Display readout Appears if... What to do
MERR (Memory error) ...the EEPROM memory cannot be
read.
• Contact service technician.
**** ... there is no communication between
the control panel and motherboard.
This appears briefly when switching on
the fixture.
• Check fuses.
• Check cable between control panel
and motherboard.
• Reinstall software.
• Contact service technician.
COER (Color wheel time-out)
RGER (Rot. gobo time-out)
FGER (Fixed gobo time-out)
GOER (Gobo index time out)
...the magnetic-indexing circuit
malfunctions (e.g. sensor defective or
magnet missing).
• After the time-out, the effect in ques-
tion stops in a random position.
• Contact service technician.
L1ER ...the software don’t detect any pulses
from the light sensor for a specific
period of time.
• Ensure that the light sensor cable is
mounted correctly on the PL54 con-
nector, or alternatively the light sen-
sors might be defective.
LERR ...the lamp cannot be struck. • Replace the lamp
shER ....there is a short circuit and the lamp
is struck without a command.
• Contact service technician.
bTER ...the temperature in the base is too
high
• Ensure that the fans are clear and
functioning and that the ambient tem-
perature does not exceed 40° C
(104° F)
• Contact service technician if the
problem persists.
PAER ...if there is a pan error and the sensor
cannot find the pan index point
• After the time-out, the fixture stops in
a random position.
• Contact service technician.
TIER ...if there is a tilt error and the sensor
cannot find the pan index point
• After the time-out, the fixture stops in
a random position.
• Contact service technician.
dRER ...if there is a drive current error. • Contact service technician.
dPER ...if there is a display programming
error.
• Contact service technician.
Table 6: Error messages