8 MAC 250 Krypton/Entour
CONFIGURING FOR LOCAL AC POWER
1 Disconnect the fixture from power.
2 Remove the 2 Phillips screws in the access cover directly behind the power and data connectors. Lift off the
cover.
3 Locate the selection switches.
4 Move the voltage switch to the setting that most closely matches the local AC voltage. If your voltage falls
halfway between 2 settings, select the higher voltage. For example, if the AC voltage is 220 V, use the 230
V setting instead of 210 V.
5 Move the frequency switch to the setting that matches the local AC frequency: 50 or 60 Hz.
6 Replace the cover.
INSTALLING A PLUG ON THE POWER CABLE
The power cable must be fitted with a grounding-type cord cap that fits your power distribution system.
Consult an electrician if you have any doubts about proper installation.
• Following the cord cap manufacturer’s instructions, connect the yellow and green wire to ground (earth), the
brown wire to live, and the blue wire to neutral. The table below shows some pin identification schemes.
APPLYING POWER
Warning! The power cables must be undamaged and rated for the electrical requirements of all
connected devices.
Important! Powering through a dimmer system can damage the fixture.
1 Verify that the supply cable is undamaged and rated for the current requirements of all connected devices.
2 Plug the prepared power cable into the AC socket and a grounded AC power supply.
Wire Pin Marking Screw color
brown live “L” yellow or brass
blue neutral “N” silver
yellow/green ground green
Table 1: Plug wiring
50
60
120
100
210
230
250
Figure 1: Power supply settings
Voltage
Frequency