32 MAC 700 Wash
Troubleshooting
Problem Probable cause(s) Remedy
One or more of the fixtures is
completely dead.
No power to fixture.
Check that power is switched on and cables are
plugged in.
Primary fuse blown (located near power inlet). Isolate fixture from power and replace fuse.
Secondary fuse(s) blown (located on PCBs in
base).
Isolate fixture from power. Check fuses and
replace.
Fixtures reset correctly but
respond erratically or not at all
to the controller.
Bad data link.
Inspect connections and cables. Correct poor
connections. Repair or replace damaged cables.
Data link not terminated.
Insert termination plug in output jack of the last
fixture on the link.
Incorrect addressing of the fixtures. Check fixture address and DMX mode settings.
One of the fixtures is defective and is
disturbing data transmission on the link.
Bypass one fixture at a time by unplugging XLR in
and out connectors and connecting them directly
together until normal operation is regained. Have
the defective fixture serviced by a qualified
technician.
XLR pin-out on fixtures does not match (pins
2 and 3 reversed).
Install a phase-reversing cable between the fixtures
or swap pins 2 and 3 in the fixture that behaves
erratically.
Time out error after fixture reset. Effect requires mechanical adjustment.
Disable effects feedback (see page 14). Contact
Martin technician for service.
Mechanical effect loses
position.
Mechanical train requires cleaning,
adjustment, or lubrication.
Contact Martin technician for service.
Lamp fails to strike after turning
the fixture off and on again, or
after a power failure.
Electronic ballast does not recognize that the
lamp is off.
Send LAMP OFF command before sending another
LAMP ON command. The lamp will then strike.
See DMX Protocol for override if
 is set to

No light and  (lamp
error) message displayed.
Lamp blown Disconnect fixture and replace lamp.
Lamp not installed Disconnect fixture and install lamp.
Lamp access safety switch open
Check that lamp access plate is fully seated and
locked in place.
Supply voltage too low Check voltage
Lamp cuts out intermittently. Fixture is too hot.
Allow fixture to cool.
Clean fixture, especially fans, vents and filters.
Reduce ambient temperature.
Table 7: Troubleshooting