Seal maintenance 59
Tighten the screws that hold the end plates, lamp access plate and
retaining ring for the front glass (or PC lens on 12° beam angle models)
gradually in stages to a torque of 2 Nm (1.5 ft.-lbs.). At this torque, the
seals will be compressed by about one-third.
When replacing the front cover, to avoid breaking the glass, tighten the
screws gradually in stages, working around in a circle.
The recommended procedure for closing each of the 4 openings is the
same:
1. Insert the screws through all holes in the cover and seal.
2. Place the cover firmly against the body. Adjust the straight sides of the
seal so that they stick out a little, just enough so that you can feel the
edge of the seal when you run a finger across the joint.
3. Cross-tighten the cover screws evenly, gradually increasing the torque in
stages to the correct setting of 2 Nm (1.5 ft.-lbs.).
If installing the eight M4 Allen screws in the front glass retaining ring or PC
lens retaining ring on the outside of the front cover, tighten screws evenly
and gradually, working around the ring in a circle, until you reach the correct
torque of 2 Nm (1.5 ft.-lbs.). If you tighten one screw too much compared to
the others, the pressure from that screw may break the front glass or lens.
Cable glands
The supplied cables enter the fixture through cable glands that fit 5.5-10 mm
(1/4 - 2/5 in.) diameter cables. The gland must be replaced if the power or
data cable is replaced with a cable of a different diameter (larger than 10
mm or smaller than 5.5 mm (1/4 - 2/5 in.), or if the data cable is replaced
with two separate cables. Replacement glands, available from electrical
suppliers, must have the following characteristics:
Temperature range 20 to 70 degrees Celsius (or better)
Ingress protection rating IP 67 or 68
Entry thread size PG 11
Minimum entry thread length 8 mm