76 Troubleshooting
Lamp does not
strike.
Ballast and transformer
settings do not match
local AC voltage and
frequency.
Disconnect fixture. Check ballast
and transformer settings and correct
if necessary.
Lamp missing or blown. Install new lamp.
Lamp is too hot. Allow lamp to cool for at least 8
minutes.
Lamp cuts out
intermittently.
Fixture is too hot. Allow fixture to cool.
Ballast and transformer
settings do not match
local AC voltage and
frequency.
Disconnect fixture. Check ballast
and transformer settings and correct
if necessary.
Defective fan. Refer to service technician.
Problem Probable cause(s) Remedy