24 MAC 250 Wash
11. Remove the two 4mm Allen screws from the carrying handles on the sides of the base unit and remove
the louvered side covers. Clean the cover louvers and base fan with a cotton swab or soft brush and
vacuum.
12. Refit the base unit covers before reapplying power.
Lubrication
The MAC 250 Wash requires no lubrication under normal circumstances. Moving parts are treated with a
long-lasting Teflon-based lubricant that can be reapplied by a Martin service partner in the unlikely event
that this should be necessary.
Replacing fuses
MAIN FUSE
The main fuse holder is built into the mains input socket.
Warning! Always replace the fuse with one of the same type
and rating!
To replace the main fuse:
1. Unplug the mains cable from the input socket.
2. Pry open the fuse holder and remove the fuse.
3. Replace the fuse with one of the same type and rating. The
fuse rating is listed on the serial number label.
4. Close the fuse holder and replace the mains cable.
POWER SUPPLY FUSES
There are two fuses for the low-voltage power supplies located on the printed circuit board. If one or more of
the green LEDs on the PCB does not light, one of these fuses may be blown. If all three LEDs are lit, the
low-voltage power supplies are functioning correctly.
To replace the low-voltage fuses:
1. Disconnect the fixture from AC power.
2. Remove the left-side yoke cover (when looking at the head from the back with the text the correct way
up as in Figure 16) to access the PCB.
F
U
SE
Figure 15: Main fuse holder
Minimum distance to flammMinimum distance to flamm
Minimum distance to illumina
Maximum ambient te
Exterior surfaceto
Figure 16: Identifying and removing the left-hand yoke cover
Comentarios a estos manuales