3. Carefully remove and check the two fuses located in the bottom of the PCB (see “Circuit board
connections” on page 34). Replace as necessary with fuses of the same size and rating (see “Fuses” on
page 37).
4. Re-attach the yoke cover.
If fuses blow repeatedly, have the fixture serviced by a Martin service technician.
Updating software
The latest MAC 250 Wash firmware is available from the support area of the Martin web site at
http://www.martin.com. It can be installed via the DMX data link using a supported Martin uploader such as
the MP-2, or via a LightJockey 4064 ISA DMX interface.
Note: Intermediate control systems such as the Martin Lighting Director (MLD) and the Martin Matrix must
be bypassed when updating fixture software via the DMX link. These systems do not relay the update code
correctly because it is not a DMX-compliant signal.
NORMAL UPDATE
To update fixture software, connect an upload device to the fixture just like a DMX controller and perform a
DMX mode upload as described in the uploaders documentation. There is no need to isolate the MAC 250
Wash from other types of fixtures on the DMX link.
After a software upload, when the MAC 250 Wash boots up it performs a check-sum test of the flash
memory and then resets. If the firmware is corrupted, a check-sum error (
) occurs. A few seconds
later the fixture displays
 and is ready for a new DMX-mode upload.
In the unlikely event that a software upload is interrupted, the fixture must be powered off for at least 10
seconds to force the check-sum test. You can repeat the DMX-mode upload as soon as
 is displayed.
BOOT SECTOR UPDATE
If the normal update procedure fails or the software update notes call for a boot-sector update, install new
software as follows:
1. Disconnect the fixture from AC power.
2. Remove the left-side yoke cover (see Figure 16) to access the PCB.
3. See “Circuit board connections” on page 34. The boot sector
jumper is located next to the plug for the control panel data
cable. Move the jumper to the Init setting. Check that the
Flash Write jumper is in the Enable position.
4. Apply power and perform a boot-mode upload as described
in the uploader manual.
5. Disconnect the fixture from AC power. Move the jumper
back to the Lock setting.
6. Re-attach the yoke cover before reapplying power.
The boot sector update can also be activated in the control panel menu under

InitLock
front
Figure 17: Boot sector jumper