30
Stand-alone operation
synchronizes its scenes with the Master, and also note that scene S4 that is
programmed in the Slave fixture will not run.
• The scene times in the Master fixture should be equal to or longer than the
corresponding scene times of the other fixtures. You may get undesirable results if,
for example, a scene is programmed in the master to last 10 seconds and in other
fixtures to fade for 15 seconds. Note that in the following example the scenes in the
Slave run out of their programmed sequence because scenes 0 and 2 on the Slave
are longer than the corresponding scenes on the Master.
MENU COMMANDS
The menu commands can be used to program and execute scenes in both DMX
Stand-Alone Mode and IR Remote Control Mode.
Note Control panel actions sometimes result in a information being
written to the fixture’s memory. If the fixture is powered off
during this process updates may be lost. A “Memory not yet
stored” warning indicator appear as a red dot in the left side of
the control panel display during memory update. Do not power
the fixture off while this is lit.
SCENE COMMANDS
Store scene (SCE/Sto): Save settings in the current scene.
F=fade, W=wait Timeline =>
M0 M1 M2 M3
Programmed in Master F W F W F W F W
S0 S1 S2 S3 S4
Programmed in Slave F W F W F W F W F W
Result M0 M1 M2 M3
FW FWF WFW
S0 S1 S2 S3
FW FW FW ----F W
M=master, S=slave
F=fade, W=wait Time >
Programmed M0 M1 M2
Master F W F W F W
S0 S1 S2
Slave F W F W F W
Result M0 M1 M2 M0 M1
Master F W F W F W F W F W
S0 S2 S1
Slave F W F W .. .. FW .. ..