Basic service
43
To clean the fan and air vents
Important! Neglecting to clean the fans and air vents can result in damage
to the fixture that is not covered by the warranty. Dust, smoke,
and grease buildup reduce the cooling air flow and will cause
the fixture to overheat. When the fixture overheats, a thermo
switch cuts power to the lamp until the fixture cools, and the
lamp cycles on and off at regular intervals.
To maintain sufficient cooling and air flow, inspect the air vents and fans at least
every 3 months or 1000 hours of operation and clean the fan and air vents by
removing dust and dirt from the fans and vent grills using a soft brush, cotton swab,
vacuum, or compressed air.
INSTALLING SOFTWARE
Firmware updates are released when features are added. The latest version is
available from the Support Area of the Martin Professional web site at
http://www.martin.dk. Firmware is installed using a Martin MP-2 uploader.
Important! Fixtures must be in a DMX mode and the data link must be
terminated.
To install software, normal method
1 Download the latest control software from the Martin Professional web site at
http://www.martin.dk. Install the software in a Martin MP-2 uploader.
2 Connect the uploader to the fixture as you would a controller. Apply power to the
uploader and the fixtures.
3 After the fixture has finished resetting, initiate the software upload as described in the
uploader manual. Wait.
4 When the upload is successfully completed, the fixture displays the new version
number and resets. Disconnect the upload device.
5 If a check-sum error (
CSE) occurs and/or the fixture does not reset, data was
interrupted or corrupted during transmission. Reattempt the upload using backup
method I, or try this procedure again.
To install software, backup method I
Follow this procedure exactly as described to install software if a normal upload
attempt is unsuccessful and a check-sum error (
CSE) occurs.
1 Disconnect the fixture from power: it must be off at least 10 seconds. Do not apply
power to the fixture until the uploader is connected and ready.